Biosensor based on a silicon nanowire field-effect transistor functionalized by gold nanoparticles for the highly sensitive determination of prostate specific antigen

Presnova Galina /G.V., Presnov Denis /D.E, Krupenin Vladimir /V., Grigorenko Vitaly /V., Trifonov Artem /A., Andreeva Irina /I., Ignatenko Olga /O., Egorov Alexey /A., Rubtsova Maya /M.Yu. Biosensor based on a silicon nanowire field-effect transistor functionalized by gold nanoparticles for the highly sensitive determination of prostate specific antigen. Biosensors and Bioelectronics , 2017 , 88. С. 283-289. ISSN 0956-5663

Полный текст не доступен из этого репозитория.
Официальный URL: http://www.elsevier.com/locate/bios

Аннотация

We have demonstrated label-free and real-time detection of prostate specific antigen (PSA) in human serum using silicon nanowire field effect transistors (NW FETs) with Schottky contacts (Si-Ti). The NW FETs were fabricated from SOI material using high-resolution e-beam lithography, thin film vacuum deposition and reactive-ion etching processes eliminating complicated processes of doping and thermal annealing. This allowed substantial simplifying the transistors manufacturing. A new method for covalent immobilization of half-fragments of antibodies on silicon modified by 3-glycidopropyltrimethoxysilane with thiol groups and 5 nm gold nanoparticles (GNPs) was established. NW FETs functionalized by GNPs revealed extremely high pH sensitivity of 70 mV/pH and enhanced electrical performance in the detection of antigen due to enhanced surface/volume ratio, favorable orientation of antibody active sites and approaching the source of the electric field close to the transistor surface. Si NWFETs were applied for quantitative detection of PSA in a buffer and human serum diluted 1/100. Response time was about 5–10 s, and analysis time per sample was 1 min. The limit of PSA detection was of 23 fg/mL, concentration range of 23 fg/mL–500 ng/mL (7 orders of magnitude). The PSA concentrations determined by the NW FETs in serum were compared with well-established ELISA method. The results matched well with the correlation coefficient of 0.97

Тип объекта: Статья
Авторы на русском. ОБЯЗАТЕЛЬНО ДЛЯ АНГЛОЯЗЫЧНЫХ ПУБЛИКАЦИЙ!: Преснова Галина, Преснов Денис, Крупенин Владимир, Григоренко Виталий, Трифонов Артем, Андреева Ирина, Игнатенко Ольга, Егоров Алексей, Рубцова Майя
Подразделения (можно выбрать несколько, удерживая Ctrl): 193 лаб. физических свойств нанокомпозитных материалов для информационных технологий
URI: http://cplire.ru:8080/id/eprint/3989
Только для зарегистрированных пользователей
Изменить объект Изменить объект